General:

  • Special HRSG for medium engine sizes
  • For fuel oil heating applications
  • Horisontal water tube boiler, with built-in steam drum
  • Built-in capacity control 
  • Natural circulation
  • Compact design (small footprint)

 

Design data:

Diesel engine output: 0.5 - 20 MWe
Engine fuel type: LFO, HFO
Exhaust gas flow: Up to 30 kg/s
Exhaust gas temperature: < 500 ºC
Steam capacity: up to ~5 t/h
Operating steam pressure: 4 - 15 bar
Steam temperature: Saturated