AV-4/AQ-2
______________________________________________________________________________________________
General:
- Standard HRSG for small gas turbines
- Smoke tube boiler, natural circulation
- Horizontal flue gas pass
- Unfired to medium-fired applications
- Can be combined with external water tube superheater
- and economizer sections
Design data:
| Gas turbine output: |
2 - 8 MWe |
| Flue gas temperature: |
< 600 ºC |
| Exhaust gas flow: |
Up to 30 kg/s |
| Steam capacity: |
5 - 15 t/h |
| Operating steam pressure: |
Max. 25 bar |
| Steam temperature: |
Saturated + 50ºC |
| Circulation: |
Natural |
|
 |
|