MISSION™ D

________________________________________________________________________________________

 

 

General

  • Standard medium pressure water tube boiler
  • Two-drum D configuration
  • Horizontal flue gas pass
  • Delivered as complete unit for easy installation
  • Available with pin tubes or bare tubes
  • Designed according to new PED/EN regulations. 

 

Design data

 

Steam capacity: 25 - 120 t/h
Heat capacity: 18 - 95 MW
Design pressure, standard: 18 bar(g)
Design pressure on request: up to 45 bar(g)
Steam temperature:

from saturation up to 

400 ºC

Efficiency (DIN 1942): 84 - 95%

 

 

Capacity, Fuel economy, Dimensions & Weight

 

 

 

Steam capacity Height "K" (incl. retraction of burner lance)
*
Total length "L"
*
Height "H"
*
Width "B" (steam drum +200) Boiler dry weight ** Boiler operation weight

kg/h

mm

mm

mm

mm

ton

ton

25,000

9,170

4,309

6,280

3,837

31.6

39.6

35,000

9,520

4,583

6,980

4,187

38.2

48.6

45,000

9,870

5,050

8,080

4,875

44.2

57.0

55,000

10,370

5,413

8,480

5,131

50.6

65.7

70,000

10,670

5,508

8,080

6,031

60.9

78.7

80,000

10,670

5,705

8,080

6,571

66.5

86.1

100,000

11,170

6,006

8,480

7,677

81.1

105.6

120,000

11,470

6,779

9,380

8,049

91.8

120.9

 

* Dimension of boiler pending final design with regards to NOx requirements, addition of superheater and/or economizer

** Boiler dry weight incl. burner, insulation, valves and refractory.

For 24 bar(g) solution, call you nearest sales office

 

DATA SHEET series
© Aalborg Industries 1999, rev.: 2.4, June 2005 (Design data are subject to change without prior notice).

 



© Aalborg Industries A/S | Gasvaerksvej 24 | 9100 Aalborg | Denmark | Terms »