________________________________________________________________________________________
| Type: |
Aalborg MD (formerly VESTA™ MD) dump condenser/drain cooler (seawater) |
| Aalborg MD (formarly VESTA™ MD-C) cooler |
| Aalborg MD-T (formaerly VESTA™ MD-T) tank washing heater |
| Size: |
Shells Ø168,3 mm x 600 mm. Up to Ø323,0 mm x 3000 mm as standard. |
| Custom sizes are available on inquiry. |
| Capacity: |
Condensers: 400-6,000 kg/h at 3 bar(g)/157 °C (condensate outlet 80 °C, sea water inlet 32 °C, outlet 50 °C |
| Lubrication oil coolers up to 1000 kW, sea-water inlet 32 °C, outlet 50 °C |
| Tank washing heaters up to 150 m3/h, sea-water inlet 5 °C, outlet 80 °C |
| Materials: |
Tubes in CuNi 90/10 alloy (VESTA™ MD-T in CuNi 70/30 alloy) |
| Tube sheets and water boxes in AlNi-bronze |
| Shell in carbon steel. |
| Fluids: |
Hot side: Steam, fresh water, thermal fluid, lubrication oil |
| Cold side: Sea-water, fresh water |
| Applications: |
Dump condenser/drain cooler for exhaust gas boilers |
| Cooler for lubrication oil, thermal oil or fresh water systems |
| Sea-water heater for tank washing with either steam or thermal oil heating |
| Different heat exchanging processes with sea or brackish water |
| Equipment: |
Thermometers, drain and vent valve, pressure gauge, control valve, steam trap, additional sensor wells |
| Approvals: |
Can be delivered with certificate from all major classification societiess |
| Delivery: |
8-12 weeks from firm order and approved drawing |
| Warranty: |
Aalborg Industries Terms & Conditions |