Go to frontpage


Marine Boilers
& Heat Exchangers
 

Alfa Laval Aalborg P

________________________________________________________________________________________

 

General

  • Exhaust gas economizer for heat recovery from diesel engines
  • Applicable for steam and hot-water generation
  • Water tube boiler with forced circulation
  • Stationary water washing and steam soot cleaning system

 

Design data

Steam capacity: 0.5 - 5.0 t/h
Hot-water capacity: 400 - 2,800 kW
Design pressure: up to 24 bar(g)




Description

Aalborg P (formerly UNEX™ P) multi-function exhaust gas economizer is a water tube, forced circulation boiler for heat recovery of diesel engine exhaust gas.

 

The heat transfer surface consists of vertical, concentric, parallel steel tube coils connected to inlet and outlet manifold pipes.

 

The rounded shape of the gas-tight steel shell surrounding the tube coils is ideal to withstand exhaust gas pulsations from the engine.

 

Vertical and straight exhaust gas passages between the tube rows – together with plain tube construction – decrease soot build-up on heating surfaces. This construction runs without problems even in the most demanding operation conditions.


The Aalborg P typically comes with built-in spark arrester and bypass damper.

 

 

 

DATA SHEET series
© Aalborg Industries 01 NOV 2010 (Design data are subject to change without prior notice).

________________

 

Related material:

 



© Alfa Laval Aalborg A/S | Gasvaerksvej 24 | 9100 Aalborg | Denmark | Terms »