General

 

  • Vertical cylindrical boiler made of mild steel
  • Standard preassembled boiler unit
  • Integrated control panel
  • Pin tube elements
  • Top-mounted fittings
  • Ready to install
  • Designed for operation with a monoblock type pressure jet or rotary cup burner

 

Design data

 

Thermal output: up to 4.6 MW
Steam capacity: 1.6 - 6.5 t/h
Design pressure: up to 10 bar(g)

 

 

Description

 

The MISSION™ OS is supplied as a standard, preassembled boiler unit. High performance is ensured by the use of the optimally designed pin-tube elements.


These elements are also used for support of the top plates of the furnace and boiler. The inclined
mounting of the burner provides good combustion with all grades.

Capacity, Fuel economy, Dimensions & Weight

 

Steam capacity Design pressure
Outside dimensions (incl. insulation)
Boiler dry weight
Boiler operation weight
A
B C D R
kg/h
bar(g)
mm
mm
mm
mm
mm
ton
ton
1,600
10
3,725 (4,530)
1,770
2,980
1,990
760
4.5 (5.1)
7.0 (9.0)
2,300
10
3,925 (4,625)
1,970
3,185
2,190
760
6.2 (6.9)

9.2 (11.4)

2,500
10
3,925 (4,740)
1,970
3,360
2,190
1,075
6.2 (7.0)
9.2 (11.7)
3,300
10
4,510 (5,120)
2,170
3,585
2,580
1,075
8.3 (9.0)
12.3 (14.6)
4,000
10
4,510 (5,345)
2,170
3,530
2,580
1,075
8.3 (9.3)
12.3 (15.4)
5,400
10
5,170 (5,910)
2,470
3,850
2,880
1,075
11.3 (12.5)
17.2 (20.7)
6,500
10
5,170 (6,135)
2,470
4,100
2,880
1,260
11.3 (12.8)
17.2 (21.8)

 

The dimensions are valid for DNV, LRS (GL, SeeBG).