Design data
| Thermal output: |
up to 4.6 MW |
| Steam capacity: |
1.6 - 6.5 t/h |
| Design pressure: |
up to 10 bar(g) |
Description
The MISSION™ OS is supplied as
a standard, preassembled boiler
unit. High performance is ensured
by the use of the optimally
designed pin-tube elements.
These elements are also used for
support of the top plates of the
furnace and boiler. The inclined
mounting of the burner provides
good combustion with all grades.
|
|
Capacity, Fuel economy, Dimensions & Weight

| Steam capacity |
Design pressure |
Outside dimensions (incl. insulation) |
Boiler dry weight |
Boiler operation weight |
A |
B |
C |
D |
R |
kg/h |
bar(g) |
mm |
mm |
mm |
mm |
mm |
ton |
ton |
1,600 |
10 |
3,725 (4,530) |
1,770 |
2,980 |
1,990 |
760 |
4.5 (5.1) |
7.0 (9.0) |
2,300 |
10 |
3,925 (4,625) |
1,970 |
3,185 |
2,190 |
760 |
6.2 (6.9) |
9.2 (11.4)
|
2,500 |
10 |
3,925 (4,740) |
1,970 |
3,360 |
2,190 |
1,075 |
6.2 (7.0) |
9.2 (11.7) |
3,300 |
10 |
4,510 (5,120) |
2,170 |
3,585 |
2,580 |
1,075 |
8.3 (9.0) |
12.3 (14.6) |
4,000 |
10 |
4,510 (5,345) |
2,170 |
3,530 |
2,580 |
1,075 |
8.3 (9.3) |
12.3 (15.4) |
5,400 |
10 |
5,170 (5,910) |
2,470 |
3,850 |
2,880 |
1,075 |
11.3 (12.5) |
17.2 (20.7) |
6,500 |
10 |
5,170 (6,135) |
2,470 |
4,100 |
2,880 |
1,260 |
11.3 (12.8) |
17.2 (21.8) |
The dimensions are valid for DNV, LRS (GL, SeeBG). |
DATA SHEET series
© Aalborg Industries 1998, rev.: 2.0, February 2008 (Design data are subject to change without prior notice).